Skip to main content
Thesis

Consumer's choice in protective eyewear

1 May 1984

Abstract

Seventeen pairs of racquetball eyewear were tested for distortion and loss of field. Four of the seventeen eyewear produced twenty five percent or greater loss of field. Two of the eyewears produced less than one percent loss of field. None produced measurable distortion utilized by our measurement techniques.